Portable Chiller
5 to 13 Tons
The SQ Service portable chillers are designed for indoor use in industrial manufacturing locations.
The chillers are produced in our ISO 9001:2000 certified facility.
Water-cooled and air-cooled units ship with a full refrigerant charge.
Units with a remote air-cooled condenser ship with a nitrogen charge.
All units are housed in a heavy guage painted steel cabinet with tool-free access.
Portable Chiller Specifications
|
|
|
|
|
|
|
Pump |
|
|
Model |
Cooling Tons |
Set Point Range °F |
Refrigerant Type |
Condenser Air Flow CFM |
Unit MCS @ 460/3/60 |
HP |
GPM |
PSI |
Shipping Weight Lbs. |
|
SQ2A05 |
5.5 |
20 - 80 |
HCFC - 22 |
4,400 |
17 |
1.5 |
13 |
43 |
575 |
|
SQ2A08 |
7.5 |
20 - 80 |
HCFC - 22 |
10,000 |
22 |
1.5 |
18 |
42 |
950 |
|
SQ2A10 |
10.0 |
20 - 80 |
HCFC - 22 |
10,000 |
27 |
1.5 |
24 |
40 |
950 |
|
SQ2A14 |
13.1 |
20 - 80 |
HCFC - 22 |
14,000 |
42 |
1.5 |
31 |
36 |
1,000 |
|
Unit MCA @ 460/3/60
|
Pump |
SQ2A05 |
|
1.5 HP |
18 |
|
3 HP |
19 |
|
3 HP, 2-stage |
19 | |
|
ADDITIONAL CHILLER SPECIFICATIONS
|
WATER CHILLERS |
ELECTRICAL |
DIMENSIONS IN FEET |
WEIGHTS |
|
Size |
Obtainable Temperatures |
Flow |
Rated Line Amps 480v |
L |
W |
H |
lbs. |
|
30 Tons |
-35° F |
30-100 CFM |
65 FLA |
120" |
94" |
82" |
6,500 |
|
40 Tons |
-35° F |
60-200 CFM |
110 FLA |
120" |
94" |
94" |
8,500 |
|
100 Tons |
-35° F |
100-300 CFM |
165 FLA |
202.5" |
94" |
102" |
14,500 |
|
150 Tons |
-35° F |
140-450 CFM |
255 FLA |
249.5" |
93" |
101" |
21,000 |
|
200 Tons |
+20° F |
300-600 CFM |
460 FLA |
226" |
92.5" |
98" |
16,000 |
|
400 Tons |
+20° F |
600-1,200 CFM |
550 FLA |
265" |
96" |
102" |
38,000 |
|
500 Tons |
+20° F |
750-1,500 CFM |
600 FLA |
264" |
96" |
96" |
19,050 |
|
1,000 Tons |
+20° F |
1,600-3,000 CFM |
1000 FLA |
336" |
96" |
96" |
35,000 |
|
Capacity |
9.6 Tons |
21.6 Tons |
| UNIT |
|
|
| Compressor Power Input |
9.7kW |
23.8kW |
| Minimum Outdoor Operating Temp |
45°F |
32°F |
| Chilled Water Flow |
22.9 Gpm |
51.8 Gpm |
Capacity control steps: 1 Minimum Capacity |
71% |
71% |
| Refrigerant |
R22 |
R22 |
| Condenser Entering Air Temp |
95°F |
95°F |
| COOLER |
|
|
| Entering Water Temp |
54°F |
44°F |
| Leaving Water Temp |
44°F |
54°F |
| Chilled Water Pressure Drop |
6.6 ft. wg |
15.4 ft. wg |
| Unit Power Input |
12.3 kw |
26.6 kw |
| Fouling Factor |
.0001 |
.0001 |
| Fluid |
FRESH WATER |
FRESH WATER |
| Pump Hp |
1.5 |
2 |
| Power Supply to Unit |
460 Volts 3 PH 60Hz |
460 Volts 3 Ph 60 Hz |
| Maximum Fuse Amps |
40 |
60 |
| Minimum Circuite Amps |
26 |
60 |
Download specifications in PDF format
Additional Specifications:
View Online Catalog
|  |